This digital water treatment control valve combines intelligent electronic controls with proven mechanical reliability. Four regeneration initiation methods—including meter immediate, meter delayed, time clock delayed, and pressure differential—allow the system to adapt to changing water demands while maintaining consistent performance.
| CLACK WS1TT SPECIFICATIONS | |
| Inlet/Outlet Fittings | ¾" to 1 ½” NPS |
| Cycles | up to 9 |
| Valve Material | Noryl (1) or equivalent |
| Regeneration | downflow / upflow |
| FLOW RATES | |
| Service @ 15 psi/1 bar drop (includes bypass and meter) | 106 lpm (6.36 m3/h) (28 gpm) |
| Backwash @ 25 psi/1.7 bar drop (includes bypass) | 57 lpm (3.40 m3/h) (15 gpm) |
| Cv Service | 7.28 |
| Cv Backwash | 2.96 |
| OPERATING PRESSURES | |
| Minimum / Maximum | 20 - 125 psi (1.4 - 8.6 bar) |
| OPERATING TEMPERATURES | |
| Minimum / Maximum | 40º - 110º F (4º – 43º C) |
| METER | |
| Accuracy | ± 5% |
| Flow Rate Range | 0.95 - 102 lpm |
| Volume Range | 0.02 - 5,700 m3 |
| Totalizer | 1 m3 - 99,999 m3 |
| DIMENSIONS & WEIGHT | |
| Distributor Pilot | 1.050” OD Pipe (¾" NPS) |
| Drain Line | ¾” or 1” NPT |
| Brine Line | ⅜” or ½” OD Poly Tube |
| Mounting Base | 2 ½” - 8 NPSM |
| Height From Top Of Tank | 7 ⅜” (187 mm) |
| Weight | 16 lbs (7.25 kg) |
| ELECTRICAL SPECIFICATIONS | |
| Supply Voltage | 200VAC to 240VAC |
| Supply Frequency | 50/60 Hz |
| Output Voltage | 15VDC |
| Output Current | 500 mA |
| TANK APPLICATIONS | |
| Water Softener | 6” – 21” diameter |
| Water Filter (2) | 6” – 21” diameter |
| CYCLES OF OPERATION (SOFTENER DOWNFLOW) | |
| Choose up to nine regeneration cycles, in any order, with a wide range of available values: | |
| Cycle | Range of times minutes |
| Backwash | 1 - 120 minutes |
| Rinse | 1 - 120 minutes |
| Pause (service) | 1 - 480 minutes |
| Brine (co-current) | 1 - 180 minutes |
| Brine (counter-current) | 1 - 180 minutes |
| Refill (softener) | 0.05 - 90.00 Kg |
| Refill (filter) | 0.2 - 76.00 Litres |